 Doseratemeter Personal Dosimeter Smeartest-NT200
6150 ADHyperLink ED 150 Smeartest-NT200
X5C Plus GPD 100
DGM-1500 Bleeper Sv
 
 Pen dosimeter  Radiation Alarm Systems Contamination Monitor
  Pen Dosimeter   Gamma Smart   Como 170
  Gamma Test1
Guardian
Doseratemeter
    
 Fluke 451B
Ion Chamber Survey Meter with Beta Slide
 High sensitivity measurements of exposure and exposure rate
• Available with dose equivalent energy response (SI units)
• Fast response to measure radiation from leakage, scatter beams and pinholes
• Ideal for a wide range of applications including NDT, x-ray, and environmental Radiation detected Alpha above 4 MeV, Beta above 100 keV, and Gamma above 7 keV
Fluke 451P
Ion Chamber Survey Meter with Beta Slide
Radiation Detected Beta above 1 MeV & gamma above 25 KeV
Operating Ranges:  0 to 500 μR/hr (0 to 5 μSv/h), 0 to 5 mR/h (0 to 50 μSv/h) 0 to 50 mR/h (0 to 500 μSv/h), 0 to 500 mR/h (0 to 5 mSv/h) 0 to 5 R/h (0 to 50 mSv/h)
Accuracy ± 10% of reading between 10% and 100% of full-scale indication on any range, exclusive of energy response (calibration source is 137Cs)
 Detector  230 cc volume air ionization chamber, pressurized to 6 atmospheres Plastic chamber wall 200 mg/cm2 thick
RDS-110
 Multi-purpose Survey Meter
Radiation detected: gamma- and X-rays, 50 keV - 1.25 MeV beta radiation with an external probe
 Detector: one halogen quenched, energy compensated GM Tube
 Measurement range: dose rate 0.05 μSv/h - 99.99 mSv/h dose 0.001 -999.9 mSv pulse rate 0.1 - 9999 CPS automatic range indication by flashing LED Signals

 
6150 AD
Dose rate meter Automess 6150 For photon radiation (gamma-and X-radiation ),Hx or H (10),with analog and digital display ,automatic range switching ,5 dose rate alarm thresholds,including 9v-battery (IEC 6LR61).
AD6/H:
Digital range : Svh/h – 10msv/h
Energy range : 60Kev----1.3Mev
Digital range : Svh/h – 1000msv/h
Energy range : 45Kev----2.6Mev
X5C Plus
 
PTB-approved doserate measuring range: 1,0 µSv/h - 20 mSv/h
Doserate indication range: 0 nSv/h - 20 mSv/h
Dose indication range: 0 nSv - 10 Sv
Energy range: 40 keV - 1,3 MeV
Doserate alarm thresholds: 4, free programmable, 1 µSv/h - 20 mSv/h
Dose alarm thresholds: 4, free programmable, 1 µSv - 10 Sv
Temperature range: -30°C up to +60°C
Dimensions / Weight: (152 x 82 x 39) mm
PTB-Approval No.: 23.51/04.01
German Fire Brigades Approval No.: DL/FW/IdF 080221/1










 






 




 









DGM-1500
Radiation detected Gamma, X-ray
Measurement unit microSv/h
Linear rage Dose rate 0,01 - 100 000 microSv/h Dose 0.001 - 1000 milliSv
Sensitivity 150 cpm/microSv/h
Accuracy ± 5 % of the reading when irradiation by Cs-137 at the calibration point at 20 deg. °C.
Linearity ± 10 % at 20 °C
Response time Fast measurement: 2,5 sec. Automatic measurement: At ambient radiation levels 3 min, at increased radiation levels (> 100 microSv/h) 5 sec. Accurasy measuremet: At ambient of low radiation level, 3 hour integration measurement. Also to measuring for gamma radiation of foodstuff.
Detector type Ambient dose equivalent-energy compensated GM-tube
Quenchinh type Neon/Halogen
Energy dependence ± 30 %, 30 keV - 1.25 Mev
Personal Dosimeter
ED 150
Dose indication range: 0,1 µSv < Hp(10) < 10 Sv
PTB-approved dose measuring range: 10 µSv < Hp (10) < 1 Sv
Doserate indication range: 0,1 µSv/h - 1,5 Sv/h
Energy range: 55 keV - 3 MeV
Dose alarm thresholds: 4 preset values in the range of 1 µSv - 10 Sv, each independently acknowledgeable
Doserate alarm thresholds: 4 preset values in the range of 1 µSv/h - 1,5 Sv/h, each independently acknowledgeable
PTB-Approval No.: -20 °C up to +60 °C
Dimensions / Weight: (136 x 40 x 17) mm
Quenchinh 23.52 / 04.01
German Fire Brigades Approval No.: DW/FW/IdF 040411
GPD 100
Dose indication range: 0,1 µSv < Hp(10)1 µSv - 10 Sv < 10 Sv
PTB-approved dose measuring range (indication with floating decimal point): 5 µSv - 10 Sv;
Doserate indication range: 0,1 µSv/h - 1 Sv/h
PTB-approved doserate measuring range: 30 µSv/h - 1 Sv/h;
Energy range: 48 keV - 2 MeV
Doserate alarm thresholds: 4, free programmable, each independently acknowledgeable;
Temperature range: 4, free programmable, each independently acknowledgeable;
Battery life: -20 °C up to +60 °C
Dose alarm thresholds: approx. 1000 h
Dimensions / Weight: (120 x 65 x 22) mm (without clip)
Dimensions / Weight: 23.03 / 96.05
Bleeper Sv  
Energy Range: 45keV to 3MeV
Dimensions: 152mm x 35mm x 23mm (max)
Display: LCD 1µSv to 999,999µSv
Weight: 106gm with batteries
Smeartest-NT200
 
 
Smeartest-NT200  
Type of instruments : Alpha & beta counter optimised for smear samles and air filters. User-friendly sotware with presentation in contamination units(Bq 2 /cm , kBq/m, Bq/m ) 2 3
Measuring  modes : Beta with auto-alpha (see the User's Manual) Beta only Alpha & Beta
Sample holder : Cup size 52x5 mm or direct insertion of smears under a clip ("mouse strap") depending on samle holdermodel.
Background compensation : The NT200 has two background compensation models.
Minimum detectable activity (MDA) : The formula is based on ISO/FDIS 11929-1 and ISO 7503-1.
Size and weight Width 186, depth 260, height 260.
Lead shield approx : 50 mm thick.
Detector : Permanently filled and sealed proportional detector (Ar, CO2).
Window diameter : 49 mm.




Pen Dosimeter
 
Pen Dosimeter
Radiation Detected: Gamma and x-ray from 16 keV to 6 MeV
Ranges: 0 –200 mR, 0 – 500 mR, 0 – 2 mSv, 0 – 5 mSv
Detector: Fiber electrometer mounted in an electrically conductive plastic ion
Detector Housing: Very low permeability plastics-hermetically sealed
Accuracy: Within + or – 10% of true exposure
Temperature Range: Dose rate independent for gamma and x-ray
PTB-Approval No.: Less than 1.0% of full scale for 24 hours at 50 C
Electrical Leakage: (136 x 40 x 17) mm
Rate Response: -20 degrees C to + 50 degrees C
Relative Humidity: Up to 90%
Dimensions: Length: 4.5” (12.4 cm) Diameter .6 “ (1.5 cm)
Weight: 1.0 oz (25 grams)
Finish: Barrel and end caps are Natural matte black with metal clip
Warranty: 2 year limited warranty
Radiation Alarm System
 
GammaSmart
 
Type of radiation: gamma radiation / X-rays
Detector: GM-tube
Sensitivity: counting rate at 3 µSv/h approx. 1 count/min
Acoustic Alarm: > 85 dB(A) measured in 30 cm distance
Temperature range: -30 °C up to +60 °C
Power supply: 3 batteries type LR1 1,5V
Dimensions / Weight:Dimensions / Weight: aluminium
Housing: (136 x 40 x 17) mm
GammaTest 1
Detector: energy-compensated GM-tube
Energy range: 48 keV - 2 MeV
Alarm thresholds: 25 µSv/h, 50 µSv/h, 1 mSv/h, 10 mSv/h
Overload capacities: > 10 Sv/h
Temperature range: -30 °C up to +60 °C
Power supply: German Fire Brigades Approval No.: 2 pcs. Mignon-cells IEC R6
(125 x 72 x 26) mm / approx. 230 g (with batteries)
Dimensions / Weight: DL/FW/GSF 127702/2
 
 
      
Guardian
The alarm provide both audible and visual indication of Gamma and X ray radiation (45KeV to 2MeV) with a loud pulsating alarm and a bright red flashing led.Sensitivity is 10uSv/hr producing pulses at 25 second intervals, though a GM tube.Background radiation produces one pulse every 20-30 minutes.
Contaminating measuring
Como 170
 
Detector type: thin-layer plastic scintillation detector with ZnS coating
Detector size: 170 cm² (mechanically protected by a honeycombed protective grid)
Background count: alpha: approx. 0,1 cps
Background count subtraction: with adjustable measuring time
Alarm: separately adjustable for each nuclide, acoustic warning
either in cps or nuclide referred in Bq or Bq/cm²
Temperature range: large, graphic LC-display 128x64 pixels, with illumination (time adjustable)
Measuring time: -10 °C up to +40 °C, special version up to -20 °C
Display of measured values: 2 batteries, AA Mignon or corresponding accumulators (NiCd, NiMH), rechargeable by recharger unit, during stationary use by wall station (option) with inductive charge conservation; operation for approx. 50 h
Dimensions / Weight: Power supply: (280 x 125 x 135) mm / length including handle approx. 750 g (batteries included)