Ultrasonic Thickness Gauges - DM5E
 | 
| 
 The DM5E series wall thickness gages enables you to accomplish a  large number of demanding tasks, especially with remaining wall  thickness measurements on components subjected to corrosion and erosion. 
The DM5E Series wall thickess gages are smart, simple-to-use  ultrasonic thickness gages that offer big ultrasonic performance in a  small lightweight package. Compact size and ergonomic shape provide  comfortable one-hand use. 
 | 
Instrument:
 | 
  | 
| Operating Principle | 
 Ultrasonic pulse-echo method | 
|  Measurement Modes | 
 Depends on Probe and Material, 0.60 mm to 508 mm (0.025” to 20.00”) in IP to 1st BW Measurement Mode, 2.00 mm to 127.0 mm 
(0.079” to 5.00”) in Dual-Multi Measurement Mode, the Coating Thickness Range Shall be 0.3 mm to 2.50 mm (0” to 0.098”). | 
|  Measuring Resolution | 
 0.01 mm Default - Selectable 0.01, 0.1 mm (0.001” Default - Selectable 0.001, 0.01”) | 
|  Material Velocity Range | 
 0.508 to 18.699 mm/msec (0.0200 to 0.7362”/msec) | 
|  Material Velocity Resolution | 
 1 m/s (0.0001”/msec) | 
|  Units | 
 Inch or Millimeter | 
|  Calibration | 
 One-Point Cal, On-Block and Off-Block, Two-Point Cal | 
|  Pulser | 
 Excitation Pulse: Spike Pulser 
Voltage: 120 V into 50 ohm Load, Using 20 MHz Oscilloscope | 
|  Receiver | 
 Bandwidth 500KHz to 12 MHz @ -3 dB 
Gain Automatic Gain Control | 
|  Display Type | 
 High-Resolution Graphical LCD, 64 x 128 Pixels, 53.0 mm x 27.0 mm with Backlight and Adjustable Contrast | 
|  Update Rate | 
 4 Hz or 8 Hz, User Selectable, 24 Hz Scan Mode Capture Rate | 
|  Thickness Value Display | 
 NORMAL View Mode 5 Digit, 10.6 mm (0.4”) High 
B-SCAN View Mode 5 Digit, 2.55 mm (0.1”) High | 
|  Display of Last Reading | 
 Solid Filled or Hollow Digits Indicate Coupled or Uncoupled Condition | 
|  Setups | 
 9 Standard Setups for Probes | 
|  Alarm Settings | 
 Minimum and Maximum Alarms, Range of 0.25 mm to 508 mm, 0. (0.010” to 20.00”) 
Reading Alternates Between Solid and Hollow When Alarms Are Enabled and Violated | 
|  Power Requirements | 
 2 “AA” Size Batteries | 
 Battery Life/Operating 
Time | 
 Approximately 60 Hours | 
|  Instrument Shut-0ff | 
 Selectable ALWAYS ON or AUTO OFF After 5, 10, 15, 30 Minutes of Inactivity | 
|  Language | 
 Selectable English, German, French, Spanish, Italian, Russian, Japanese and Chinese | 
|  I/O Connectors | 
 Transducer Dual Lemo 00 (coax) 
Mini-USB Mini-USB to PC | 
|  Temperature | 
Operating -10°C to +50°C (+10°F to +120°F) 
Storage -20°C to +60°C (-10°F to +140°F)  | 
|  Weight | 
 223 g (0.597 lb) Including Batteries | 
|  Size | 
 138 mm x 32 mm x 75 mm | 
|  Shock | 
 IEC 68-2-27 Ea, as per Mil Std 810C Method 516.2 Procedure I with a 15g  11ms Impulse Half Sinusoidal Wave Applied 6 Times per Axis | 
|  Sealing | 
 IEC529 / IP54, Dust Proof/Dripping Water Proof as per IEC 529 Specifications for IP54 Classification | 
              
Data Record Option Features:
 | 
  | 
|  Capacity | 
 50,000 Readings | 
|  File Structures | 
 Grid File | 
|  Number of Rows | 
 1 to 50,000 | 
|  Number of Columns | 
 1 to 223 | 
|  File Naming | 
 Up to 24 Character Alphanumeric Name | 
|  Optional Software | 
 UltraMATE and UltraMATE Lite | 
              
Probe/Transducers:
 | 
  | 
    |